A fixed-mounted fuse switch disconnector is installed at a defined position inside the switchboard using a mechanical mounting structure such as bolts and mounting holes.
The switch has a dedicated installation position, and its electrical connections are then made according to the cabinet’s busbar or cable arrangement.
For GRL’s DNH1G series, the fixed installation versions use the /30G model designation. The product drawings provide specific fixed-installation dimensions and mounting-hole arrangements for different current ratings.
Fixed-Mounted Fuse Switch Installation:
Switchboard mounting plate → Mounting holes → fuse switch disconnector→ Electrical connection → Outgoing circuit
This approach is straightforward when the switchboard has already been designed around fixed component positions.
For example, a cabinet manufacturer may have a standard mounting plate with predefined positions for several protection devices. Each fuse switch is installed at its assigned position and connected to the corresponding electrical circuit.
A busbar-mounted fuse switch disconnector is designed to be installed directly onto a compatible busbar system.
Instead of treating the fuse switch and the busbar as two completely separate installation structures, the busbar becomes part of the mechanical and electrical arrangement.
GRL’s DNH1G series includes busbar-mounted versions identified by the /31G designation for the relevant models. The manufacturer’s documentation provides separate dimensions for busbar installation.
Busbar-Mounted Fuse Switch Installation:
Busbar → Mounting interface → Fuse switch → Outgoing circuit
GRL’s product information describes the busbar version as a hanging type that can be mounted on the busbar without drilling installation holes, unlike the fixed version.
This makes the installation architecture fundamentally different from a conventional fixed-mounted arrangement.

The easiest way to understand the difference is to compare the installation process rather than the appearance of the two switches.
| Feature | Fixed-Mounted | Busbar-Mounted |
|---|---|---|
| Mounting method | Fixed to a mounting structure | Mounted directly onto a compatible busbar system |
| Typical GRL DNH1 designation | /30G | /31G |
| Busbar preparation | May require drilled mounting holes | Designed for direct busbar mounting interface |
| Mechanical installation | Bolted installation | Hang-on / busbar mounting arrangement |
| Positioning | Defined by mounting structure | Determined by compatible busbar arrangement |
| Cabinet layout | Traditional fixed-component layout | Busbar-based modular layout |
| Modification | May require mechanical changes | Can be more flexible within the compatible busbar system |
| Best suited to | Conventional fixed switchboards | Busbar distribution systems |
The difference is therefore primarily about installation architecture, not the basic protection purpose of the fuse switch.
Potentially, yes—but it is important to understand what is actually being saved.
A busbar-mounted fuse switch does not necessarily have a dramatically smaller body than its fixed-mounted counterpart. The potential space advantage comes from how the switch, busbar, mounting structure, and electrical connections are arranged together.
With fixed installation, the cabinet designer may need to allocate space for:
With a busbar-mounted system, some of these installation requirements can be integrated into the common busbar architecture.
Where the Space Difference Comes From
Fixed: Mounting structure + Fuse switch + Connection hardware + Cable routing
Busbar-mounted: Busbar + Mounting interface + Fuse switch + Outgoing connection
This is why busbar mounting can be particularly useful when several fuse switches need to be installed in one distribution cabinet.
However, the actual cabinet-space saving depends on the complete switchboard design. It should be calculated from the installed equipment, busbar arrangement, connection requirements, and required maintenance clearances rather than assuming a fixed percentage for every application.
The installation process is another important difference.
With a fixed-mounted fuse switch, the cabinet manufacturer normally needs to establish the mounting position, prepare the mounting holes, secure the device, and then complete the electrical connection.
With a busbar-mounted fuse switch, the mounting interface is designed around the busbar system. GRL specifically states that its busbar-mounted DNH1 design can be hung onto the busbar without drilling mounting holes in the busbar, while the fixed version requires holes to be prepared for bolted installation.
| Installation Step | Fixed Type | Busbar Type |
|---|---|---|
| Determine mounting position | Required | Defined by busbar arrangement |
| Prepare mounting holes | Typically required | Not required in the same way |
| Install mounting hardware | Required | Integrated with busbar mounting method |
| Install fuse switch | Bolt to mounting structure | Hang / mount onto compatible busbar |
| Complete electrical connections | Separate connection arrangement | Integrated with busbar-based distribution architecture |
| Change component position | May require new mounting work | Can be more flexible within the compatible system |
This difference can become significant when a cabinet contains many outgoing protection devices rather than just one fuse switch.
Fixed mounting can be a practical choice when the switchboard already uses a conventional fixed-component architecture.
It may be appropriate when:
In these situations, changing to a busbar-mounted solution may provide little practical benefit if the rest of the cabinet is still designed around fixed mounting.
The key is to evaluate the complete cabinet rather than choosing the mounting method in isolation.
Busbar mounting becomes more attractive when the distribution cabinet is designed around a common busbar system.
It can be particularly relevant when:
GRL’s DNH1G product family provides both fixed and busbar installation options across several current ratings, allowing the mounting method to be selected according to the switchboard architecture.
Maintenance requirements should also be considered when selecting the mounting method.
A fixed-mounted switch is installed at a defined location, so maintenance personnel know exactly where the device is located. This can work very well in a standardized switchboard where the component arrangement rarely changes.
A busbar-mounted architecture can provide more flexibility when the distribution system needs to be modified. GRL’s busbar system documentation describes a modular arrangement in which components can be repositioned or swapped within the system.
This can be useful for switchboards that may later require:
However, this flexibility depends on the compatibility of the busbar, mounting interface, current rating, clearances, and the complete switchboard design. A busbar-mounted switch should not be moved simply because there is an available physical position.
Consider a 250A low-voltage distribution cabinet.
If the cabinet is designed around a conventional mounting plate, the fixed version DNH1-250/30G can be selected for the fixed installation arrangement.
If the same distribution section is designed around a compatible busbar system, the busbar-mounted DNH1-250/31G can be considered instead. GRL’s documentation identifies these as the fixed and busbar versions of the 250A product respectively.
| 250A Application | Fixed Design | Busbar Design |
|---|---|---|
| GRL model example | DNH1-250/30G | DNH1-250/31G |
| Mounting concept | Fixed | Busbar-mounted |
| Mounting preparation | Mounting-hole arrangement | Busbar mounting interface |
| Typical cabinet architecture | Mounting plate based | Busbar based |
| Suitable design priority | Conventional fixed installation | Modular busbar distribution |
The important lesson is that the two models should not be selected only by comparing the 250A rating. They are intended for different installation architectures.

DNH1 Fuse Switch Disconnector
There is no universal answer because both installation methods serve legitimate switchboard designs.
Choose fixed mounting when the cabinet uses a conventional mounting structure, component positions are defined, and a bolted installation fits the project’s mechanical and electrical arrangement.
Choose busbar mounting when the switchboard is built around a compatible busbar system and the project benefits from modular installation, simplified mounting, multiple outgoing feeders, or more flexible component arrangement.
The most important point is to select the fuse switch together with the cabinet architecture. A busbar-mounted switch provides the most value when the rest of the distribution system is designed to take advantage of busbar mounting.
Key takeaway: Fixed and busbar-mounted fuse switch disconnectors can provide the same basic switching and protection function, but their installation architectures are different. Fixed types are designed around conventional mounting structures, while busbar-mounted types integrate the fuse switch into a compatible busbar distribution system. The right choice depends on your cabinet layout, installation method, space constraints, and future modification requirements.
GRL’s DNH1G fuse switch disconnector family is available in both fixed and busbar-mounted configurations. Depending on the model, the series supports different current ratings and NH fuse sizes, with optional functions such as auxiliary contacts, microswitches, and fuse monitoring.
If you are designing an LV switchboard, provide your rated current, system voltage, NH fuse size, busbar arrangement, mounting method, number of outgoing feeders, and available cabinet space. GRL can help you identify a suitable fuse switch configuration.
Request Fuse Switch Selection Support | Explore DNH1G Fuse Switch Disconnectors | Explore the GRL Busbar System
A practical selection process starts with the cabinet rather than the fuse switch.
| Question | If Yes | Likely Direction |
|---|---|---|
| Does the cabinet already use a compatible busbar system? | Yes | Consider busbar-mounted |
| Are multiple outgoing fuse switches required? | Yes | Consider busbar-mounted |
| Is the switch installed on a conventional mounting plate? | Yes | Consider fixed-mounted |
| Are component positions unlikely to change? | Yes | Fixed mounting may be suitable |
| Is cabinet space highly constrained? | Yes | Evaluate busbar-mounted layout |
| Does the project require a standardized bolted installation? | Yes | Fixed mounting may be more appropriate |
| Will the distribution layout need future modification? | Yes | Evaluate a modular busbar architecture |
After choosing the mounting method, the remaining electrical parameters still need to be verified.
These include: